| Applies when | chlorine dioxide, clo2 |
|---|---|
| Recommend instead | Peabody Engineering () |
| Rationale | Chlorine dioxide, 1.9 specific gravity. Peabody's Special Application Tanks guidance lists this alongside sulfuric acid, sodium hypochlorite, and hydrogen peroxide as one of the oxidizer chemistries requiring Linear PE (not cross-linked XLPE) tank material - Peabody explicitly does not recommend XLPE tanks with a linear liner for any of these four oxidizers. |
| Confidence | confirmed |
| Source | vendor-sources/peabody-general-catalog.md |
This is a general engineering rule derived from real field/case-study evidence, not a substitute for a project-specific specification review — confirm against your exact process conditions before ordering equipment.
All engineering rules → · Download full ruleset (JSON) →
Source: Liberty Chemical Equipment & Supply, Inc. (LibertyCES) — engineering data compiled from real vendor and field-verified sources. For a free spec review, call James Riggins at (559) 395-5500 or email [email protected] / [email protected]. Website: libertyces.com.